FEATURES
·
Packaged double-duct straight
cooling and heat pump air conditioner without outdoor unit
·
Water radiator
·
Water-cooled air-conditioner;
Water/air heat pump (according to standard EN14511)
·
Water condensation with a water avarage consumption of about 1 cubic meter for a 8 hour
operation
·
To be freely installed, not
necessarily on a perimetral wall, because no holes in
the wall are requested
·
Designed to operate with both town
water and wellwater or groundwater; it can be used
also as terminal unit of a closed circuit system (water loop) with water at
30°C, according to EN14511 standard specifications
·
High efficiency spiral heat
exchanger
·
Solenoid valve to stop the town
water flowrate when the compressor is off
·
Anti-freeze protection on the
condensation water circuit
·
It's suggested the installation of
a filter to be inspected on the entry of the town water (by the installer)
·
Automatic change-over between
cooling and heating modes
·
Infrared remote control with 4
digital timers to be set on the 24h and week-end
·
Double temperature sensor (on the
unit and inside the remote control)
·
Double temperature indication (set
and room)
·
"I Feel" feature
·
Dry only feature
·
Ventilation only feature
·
"Sleep" function with
night set-back capability
·
Horizontal flap swinging or to be
set to a fixed position by remote control
·
Vertical flap by manual control
·
Washable filters
·
Three-speed tangential fan with
auto or speed manual selection
·
Cold Draft Prevention" device
with water temperature < 40°C in water radiator mode and with evaporator
temperature < 40°C in heat pump mode
·
High precision thermostat with
adjustment from 6°C to 40°C in water radiator mode
·
Heating function disabled during
defrosting cycle
·
Auto restart after a black out,
saving all feature parameters set before the power failure
·
Electronic protection against
over-pressures
·
HFC refrigerant R410A
·
High efficiency rotary compressor
·
Optional joint kit for hydraulic
connection to the heating plant (necessary only in water radiator mode)
·
Three-way bypass valve included in
the water connection module
·
Special optional support kit of
two small feet for floor installations (glass walls, etc.)