Heat pump Cassette Indoor units for
MINISET and MULTISET VRF systems
-
Infrared remote controller or wired
remote controller (option)
-
Special system to avoid condensate
dripping
from air outlet ribs
-
Integrated pump for condensate discharge
-
New three-speed centrifugal fan,
granting low
noise air
diffusion
|
- Automatic change-over between cooling and heating
modes.
- Special function during heat pump start-up and
defrosting cycle to avoid cool air emission in the room.
- Among the control units available for this kind
of indoor unit (all optional):
- the infrared remote control, equipped with a 24h digital
timer and a temperature sensor granting automatically
the best comfort conditions ("I Feel" feature);
- a special wired controller with configuration, diagnostic and
weekly timer capabilities, which can be matched with weekly timer
and control system.
- Temperature sensor integrated in the infrared
remote contoller.
- Night set back capability.
- "I Feel" feature, granting the best comfort
conditions.
- Dry function.
- New three-speed centrifugal fan by remote control,
granting a better and low noise air diffusion.
- Four horizontal flaps swinging or to be set on
a fixed position by remote control
- These flaps are equipped with a special system
to avoid condensate dripping from air outlet ribs.
- Anti-mould and anti-bacteria washable filters
- Integrated pump for condensate discharge
- Possibility to have a connection for fresh air
intake
(CAFM255-365-485)
- Double-way of air duct in adjacent rooms
through pre-drilled holes
(CAFM255-365-485).
- Dynamic refrigerant control by DC Inverter
compressor and circuit, electronic valve and fuzzy logic managed by
a powerful microprocessor.
INDOOR UNITS for MINISET
and MULTISET VRF |
CAFM 75 R5I |
CAFM 95 R5I |
CAFM 125 R5I |
CAFM 165 R5I |
CAFM 185 R5I |
Features |
Unit |
Cooling |
Heating |
Cooling |
Heating |
Cooling |
Heating |
Cooling |
Heating |
Cooling |
Heating |
Cooling /
Heating capacity |
kW |
2,20 |
2,50 |
2,80 |
3,20 |
3,60 |
4,20 |
4,70 |
5,20 |
5,60 |
6,30 |
BTU/h |
7.500 |
8.520 |
9.550 |
10.920 |
12.280 |
14.320 |
16.020 |
17.740 |
19.100 |
21.480 |
kcal/h |
1.890 |
2.150 |
2.410 |
2.750 |
3.100 |
3.610 |
4.040 |
4.470 |
4.820 |
5.420 |
Air flowrate (HS-MS-LS) |
m³/h |
700/600/500 |
700/600/500 |
700/600/500 |
750/630/530 |
750/630/530 |
Dehumidification |
l/h |
0,9 |
1,0 |
1,2 |
2,3 |
2,3 |
Fan speeds |
n° |
3 + Auto |
3 + Auto |
3 + Auto |
3 + Auto |
3 + Auto |
Sound pressure level (HS-MS-LS)
at 2 m |
dB(A) |
43-40-37 |
43-40-37 |
43-40-37 |
44-40-37 |
44-40-37 |
Sound power level (HS-MS-LS) |
dB(A) |
52-49-46 |
52-49-46 |
52-49-46 |
53-49-46 |
53-49-46 |
Power supply |
V/Ph/Hz |
230/1/50 |
230/1/50 |
230/1/50 |
230/1/50 |
230/1/50 |
Power input |
kW |
0,087 |
0,087 |
0,087 |
0,087 |
0,087 |
0,087 |
0,087 |
0,087 |
0,087 |
0,087 |
Running current |
A |
0,41 |
0,41 |
0,41 |
0,41 |
0,41 |
0,41 |
0,41 |
0,41 |
0,41 |
0,41 |
Refrigerant type |
|
R410A |
R410A |
R410A |
R410A |
R410A |
Liquid pipe diameter |
mm (inches) |
6,35(1/4") |
6,35(1/4") |
6,35(1/4") |
6,35(1/4") |
6,35(1/4") |
Gas pipe diameter |
mm (inches) |
12,70(1/2") |
12,70(1/2") |
12,70(1/2") |
12,70(1/2") |
12,70(1/2") |
Internal diameter of
condensate drain pipe |
mm |
18 |
18 |
18 |
18 |
18 |
Net weight O.U./grill |
Kg |
16/2,5 |
16/2,5 |
16/2,5 |
18/2,5 |
18/2,5 |
Net dimension (H./W./D.) |
mm |
273x575x575 |
273x575x575 |
273x575x575 |
273x575x575 |
273x575x575 |
Net dimension
grill (H./W./D.) |
mm |
64x730x730 |
64x730x730 |
64x730x730 |
64x730x730 |
64x730x730 |
INDOOR UNITS for MINISET
and MULTISET VRF |
CAFM 255 R5I |
CAFM 365 R5I |
CAFM 485 R5I |
Features |
Unit |
Cooling |
Heating |
Cooling |
Heating |
Cooling |
Heating |
Cooling /
Heating capacity |
kW |
7,30 |
8,00 |
10,60 |
11,40 |
14,00 |
16,00 |
BTU/h |
24.890 |
27.280 |
36.150 |
38.880 |
47.740 |
54.560 |
kcal/h |
6.280 |
6.880 |
9.120 |
9.800 |
12.040 |
13.760 |
Air flowrate (HS-MS-LS) |
m³/h |
1.140/1.020/840 |
1.920/1.680/1.320 |
1.920/1.680/1.320 |
Dehumidification |
l/h |
3,6 |
4,6 |
6,3 |
Fan speeds |
n° |
3 + Auto |
3 + Auto |
3 + Auto |
Sound pressure level (HS-MS-LS)
at 2 m |
dB(A) |
47-45-41 |
53-50-46 |
53-50-46 |
Sound power level (HS-MS-LS) |
dB(A) |
56-54-50 |
62-59-55 |
62-59-55 |
Power supply |
V/Ph/Hz |
230/1/50 |
230/1/50 |
230/1/50 |
Power input |
kW |
0,175 |
0,120 |
0,210 |
0,150 |
0,210 |
0,150 |
Running current |
A |
0,6 |
0,37 |
0,92 |
0,65 |
0,92 |
0,65 |
Refrigerant type |
|
R410A |
R410A |
R410A |
Liquid pipe diameter |
mm (inches) |
9,52(3/8") |
9,52(3/8") |
9,52(3/8") |
Gas pipe diameter |
mm (inches) |
15,88(5/8") |
15,88(5/8") |
15,88(5/8") |
Internal diameter of
condensate drain pipe |
mm |
32 |
32 |
32 |
Net weight O.U. |
Kg |
22/6 |
27/8 |
27/8 |
Net dimension (H./W./D.) |
mm |
338x860x860 |
338x1.150x860 |
338x1.150x860 |
Net dimension
grill (H./W./D.) |
mm |
30x860x860 |
30x1.150x860 |
30x1.150x860 |
|
|
-
3-way Outdoor units
2-way Outdoor units
Miniset Outdoor units