Complete range from 2,70
to 6,50 kW
-
Able to operate up -15°C of
outdoor air temperature
-
New design elegant
and compact
-
Class A
-
Quiet and user
friendliness
-
Condensate discharge
right or left
-
New outdoor units, very
compact
|
- Straight cooling split air conditioner able to
operate up -15°C of outdoor air temperature
- Single-phase and three-phase versions (188 and
228 models).
- Ozone friendly refrigerant R410A (HFC)
- Infrared remote control; 24h digital timer;
4-addressing possibility
- Double temperature sensor (on the unit and inside
the remote control)
- "I Feel" feature, granting the best comfort
conditions
- Dry function
- Three-speed tangential fan by remote control
- Night set-back capability
- Horizontal flap by remote control: swinging or
six fixed positions
- The design ensures an easy
installation and the full compliance with EN60335 safety standard
allows you to install the unit even at any height on the wall
- Usable also without remote cotrol
- Washable filters; active carbon filters
(optional)
- Auto restart after a power supply black out
- Electronic protection of the indoor units:
anti-freeze; heating function disabled during defrosting cycle,
electronic protection against over-pressures.
- Service contact to make the unit operating or
not operating
- Double condensate discharge (right/left) to make
easier the installation
- Self-diagnostic functions
- High efficiency rotary compressor
|
MATCHING |
CSMRF 98 L5 |
CSMRF 128 L5 |
Indoor unit |
|
MRAF 98 C5T |
MRAF 128 C5T |
Outdoor unit |
230/1/50 |
GRF 98 L5T |
GRF 128 L5T |
|
400/3N/50 |
|
|
|
|
Cooling |
Cooling |
Cooling
capacity |
kW |
2,70 |
3,40 |
BTU/h |
9.215 |
11.600 |
kcal/h |
2.322 |
2.924 |
Energy label class |
ABCDEFG |
A |
A |
E.E.R./C.O.P. |
(kW/kW) |
3,51 |
3,24 |
Air
flowrate Indoor (h.-m.-l.) |
m3/h |
450-400-370 |
470-430-390 |
Dehumidification |
l/h |
0,8 |
1,5 |
Fan speeds (Indoor /
Outdoor) |
n° |
3 + Auto/1 |
3 + Auto/1 |
Sound pressure Indoor
(h.-m.-l.) at 2 m |
dB(A) |
41-36-32 |
41-36-32 |
|
Sound Power Indoor (h.-m.-l.) |
dB(A) |
50-45-41 |
50-45-41 |
Sound pressure Outdoor
(h.) at 4 m |
dB(A) |
38 |
40 |
|
Sound Power Outdoor (hl.) |
dB(A) |
57 |
60 |
Power input / Runnning
Consumption |
kW / A |
0,77 / 3,4 |
1,05 / 4,7 |
Annual energy cons.-
cooling mode (500h) - Directive 2002/31/CE |
kWh |
385 |
525 |
Compressor type |
|
Rotary |
Rotary |
Refrigerant type |
|
R410A |
R410A |
Liquid pipe diameter |
mm(") |
6,35(1/4") |
6,35(1/4") |
Gas pipe diameter |
mm(") |
9,52(3/8") |
12,7(1/2") |
Max. pipe lenght with
gas standard charge |
m |
7,5 |
7,5 |
Max. pipe lenght with
gas additional charge |
m |
15 |
15 |
Gas additional charge |
gr/m |
15 |
20 |
Max. height between
units |
m |
7 |
7 |
External diameter of condensate
drain pipe |
mm |
18 |
18 |
Net weight Indoor /
Outdoor |
Kg |
8/35 |
8/35 |
Net dimension Indoor (H./W./D.) |
mm |
270x805x214 |
270x805x214 |
Net dimension Outdoor
(H./W./D.) |
mm |
540x700x265 |
540x700x265 |
|
MATCHING |
CSMPF 188 L5 |
CSMPF 188 L7 |
CSMPF 228 L7 |
Indoor unit |
|
MPAF 188 C5T |
MPAF 188 C5T |
MPAF 228 C5T |
Outdoor unit |
230/1/50 |
GRF 188 L5T |
|
|
|
400/3N/50 |
|
GRF 188 L7T |
GRF 228 L7T |
Features
|
Cooling |
Cooling |
Cooling |
|
Cooling
capacity |
kW |
5,20 |
5,30 |
6,50 |
BTU/h |
17.750 |
18.073 |
22.180 |
kcal/h |
4.472 |
4.560 |
5.590 |
Energy label class |
ABCDEFG |
A |
A |
B |
E.E.R./C.O.P. |
(kW/kW) |
3,25 |
3,21 |
3,13 |
Air
flowrate Indoor (h.-m.-l.) |
m3/h |
760-630-550 |
760-630-550 |
830-720-630 |
Dehumidification |
l/h |
2,0 |
2,0 |
2,5 |
Fan speeds (Indoor /
Outdoor) |
n° |
3 + Auto/1 |
3 + Auto/1 |
3 + Auto/1 |
Sound pressure Indoor
(h.-m.-l.) at 2 m |
dB(A) |
46-41-37 |
46-41-37 |
49-45-42 |
|
Sound Power Indoor (h.-m.-l.) |
dB(A) |
55-50-46 |
55-50-46 |
58-54-51 |
Sound pressure Outdoor
(h.) at 4 m |
dB(A) |
45 |
45 |
48 |
|
Sound Power Outdoor (hl.) |
dB(A) |
65 |
65 |
68 |
Power input / Runnning
Consumption |
kW / A |
1,6 / 7,1 |
1,65 / 3,40 |
2,08 / 4,20 |
Annual energy cons.-
cooling mode (500h) - Directive 2002/31/CE |
kWh |
800 |
725 |
1040 |
Compressor type |
|
Rotary |
Rotary |
Rotary |
Refrigerant type |
|
R410A |
R410A |
R410A |
Liquid pipe diameter |
mm(") |
6,35(1/4") |
6,35(1/4") |
9,52(3/8") |
Gas pipe diameter |
mm(") |
12,7(1/2") |
12,7(1/2") |
15,88(5/8") |
Max. pipe lenght with
gas standard charge |
m |
7,5 |
7,5 |
7,5 |
Max. pipe lenght with
gas additional charge |
m |
20 |
20 |
30 |
Gas additional charge |
gr/m |
25 |
25 |
25 |
Max. height between
units |
m |
7 |
7 |
7 |
External diameter of condensate
drain pipe |
mm |
18 |
18 |
18 |
Net weight Indoor /
Outdoor |
Kg |
12/52 |
12/52 |
12/69 |
Net dimension Indoor (H./W./D.) |
mm |
285x995x237 |
285x995x237 |
285x995x237 |
Net dimension Outdoor
(H./W./D.) |
mm |
630x830x305 |
630x830x305 |
735x940x340 |
The technical data
here indicated are in compliance with the European standard EN14511
- Directive 2002/31/EC
|
Infrared remote control with digital timer and temperature sensor inside
|