Floor/ceiling split air conditioners
for residential applications
-
Low ambient version
-
Single-phase and three-phase models
(185 -
225)
-
Ozone friendly refrigerant R410A
-
Multifunctional infrared remote control
-
Optional active carbon filters
|
- Low ambient split air conditioners
for Floor or Ceiling installation.
- Single-phase and three-phase models (185 - 225)
.
- Ozone friendly refrigerant R410A.
- Infrared remote control with digital timer to be
set on the 24h and week-end.
- Double temperature sensor (on the unit and
inside the remote control).
- "I Feel" feature, granting the best comfort
conditions.
- Dry function.
- Three-speed tangential fan by remote control.
- Night set back capability.
- Horizontal flap swinging by remote control, granting a perfect temperature homogeneity..
- Vertical flap by manual control.
- Anti-mould and anti-bacteria washable filters;
optional active carbon filters.
- Auto restart after a power supply black out.
- Electronic protection against over-pressures.
- High efficiency rotary compressor.
COOLING ONLY MODELS -"
L" VERSION (low ambient) |
|
SKPF 125 L5 |
SKPF 185 L5/L7 |
SKPF 225 L5/L7 |
Indoor unit |
|
KPAF 124 R5 T |
KPAF 185 R5 T |
KPAF 225 R5 T |
Outdoor unit |
230/1/50 |
GRF 125 L5 T |
GRF 185 L5 T |
GRF 225 L5 T |
|
400/3N/50 |
|
GRF 185 L7 T |
GRF 225 L7 T |
|
Unit |
Cooling |
Cooling |
Cooling |
Cooling capacity |
kW |
3,60 |
5,65 |
6,80 |
BTU/h |
12.280 |
19.270 |
23.190 |
kcal/h |
3.096 |
4.860 |
5.850 |
Energy efficiency class |
ABCDEFG |
A |
A |
B |
E.E.R. |
(kW/kW) |
3,21 |
3,32 |
3,02 |
Air flowrate (HS-MS-LS) |
m3/h |
700-590-500 |
800-700-590 |
840-770-670 |
Dehumidification |
l/h |
1,3 |
2,3 |
3,3 |
Fan speeds (I.U. / O.U.) |
n° |
3 + Auto / 1 |
3 + Auto / 1 |
3 + Auto / 1 |
Sound pressure level I.U. (HS-MS-LS)
at 2 m |
dB(A) |
47-43-38 |
51-47-43 |
52-49-46 |
Sound power level I.U. (HS-MS-LS) |
dB(A) |
55-51-46 |
58-55-52 |
60-57-54 |
Sound pressure level O.U. (HS) at 4 m |
dB(A) |
42 |
48 |
47 |
Sound power level O.U. (HS) |
dB(A) |
62 |
68 |
67 |
Power input / Running current |
kW / A |
1,120 / 4,90 |
1,700 / 7,80 |
2,250 / 10,00 |
Annual energy consumption in Cooling
mode - (500h) |
kWh |
560 |
850 |
1125 |
Compressor type |
|
Rotary |
Rotary |
Rotary |
Refrigerant type |
|
R410A |
R410A |
R410A |
Liquid pipe diameter |
mm(inches) |
6,35(1/4") |
6,35(1/4") |
9,52(3/8") |
Gas pipe diameter |
mm(inches) |
9,52(3/8") |
12,7(1/2") |
15,88(5/8") |
Max. pipe lenght with gas standard
charge |
m |
7,5 |
10 |
12,5 |
Max. pipe lenght with gas
additional charge |
m |
15 |
25 |
20 |
Gas additional charge |
gr/m |
12 |
20 |
20 |
Max. height between units |
m |
7 |
15 |
15 |
Internal diameter of condensate
drain pipe |
mm |
18 |
18 |
18 |
Net weight I.U. / O.U. |
Kg |
23,5/36 |
23,5/56 |
23,5/74 |
Net dimension I.U. (H./W./D.) |
mm |
680x900x190 |
680x900x190 |
680x900x190 |
Net dimension O.U. (H./W./D.) |
mm |
610x795x290 |
690x846x302 |
680x900x340 |
The technical data
here indicated are in compliance with the European standard EN14511
- Directive 2002/31/EC
| |
Infrared remote control with digital timer and temperature sensor inside
|