Rêve 248 C H2O
-
Cooling only air conditoner + water radiator
-
Water-cooled; pressostatic valve fitted
-
To be freely installed: not necessarily on a perimetral wall,
without holes in the wall
-
Very high energy efficiency
-
Very low energy consumption
-
External sound level lower than the
air-condensed version
-
Ozone friendly refrigerant: R410A
|
- Packaged double-duct straight cooling
air-conditioner + water radiator (with optional joint kit for
connection to the heating plant)
- Water-cooled condensation with a water medium consumption
of about 1 m3 for a 8 hour operation.
- To be freely installed, not necessarily on a
perimetral wall, because no holes in the wall are requested.
- Designed to operate with both town water and
wellwater or groundwater; it can be used also as terminal unit of a
closed circuit system (water loop) with water at 30°C, according to
EN14511 standard specifications.
- High efficiency spiral heat exchanger.
- With pressostatic valve fitted (town water)
- Anti-freeze protection on the condensation water
circuit.
- It's suggested the installation of a filter to be
inspected on the entry of the town water (by the installer).
- Infrared remote control with 24h digital timer
.
- Double temperature sensor (on the unit and
inside the remote control); double temperature indication (set and
room).
- Dry only function.
- Ventilation only function.
- "I Feel" feature, granting the best comfort
conditions.
- "Sleep" feature, with automatic
adaptation to the night temmperatures.
- Horizontal flap swinging or to be set to a
fixed position by remote control.
- Vertical flap by manual control.
- Anti-mould and anti-bacteria washable filters.
- Three-speed tangential fan with auto or speed
manual selection.
- "Cold Draft Prevention" device with water
temperature < 40°C in water radiator mode.
- High precision thermostat with adjustment from
6°C to 40°C in water radiator mode.
- Auto restart after a black out, saving all
feature parameters set before the power failure.
- Electronic protection against over-pressures.
- Optional joint kit for hydraulic connection to
the heating plant (with three-way bypass valve included) necessary
only in water radiator mode.
- Special optional support kit of two small feet
for floor installations (glass walls, etc.).
- HFC refrigerant R410A.
- High efficiency rotary compressor.
MODEL |
MROF 248 C5T |
Operation |
with
town water |
in
water loop*
(standard conditions EN14511) |
Features |
Unit |
Cooling |
Cooling |
Cooling capacity in air-conditioner mode |
kW |
2,83 |
2,7 |
BTU/h |
9.650 |
9.200 |
kcal/h |
2.430 |
2.320 |
Energy efficiency class |
ABCDEFG |
- |
B |
E.E.R. |
(kW/kW) |
4,42 |
4,15 |
Air flowrate (HS-MS-LS) |
m³/h |
330-300-280 |
Dehumidification |
l/h |
1,2 |
1,2 |
Fan speeds |
n° |
3 + Auto |
3 + Auto |
Sound pressure level
at 2 m/ Sound power level - air-conditioner mode (HS-MS-LS) |
dB(A) |
44-42-41/52-50-49 |
44-42-41/52-50-49 |
Power supply |
V/Ph/Hz |
230/1/50 |
Power
input
/ Running current in air-conditioner mode |
kW / A |
0,640 / 2,9 |
0,650 / 2,9 |
Annual energy consumption in Cooling
mode - (500h) |
kWh |
- |
325 |
Water flowrate
for the heat exchanger |
m³/h |
0,150 |
0,525 |
Pressure drops |
KPa |
2,9 |
38,0 |
Refrigerant type |
|
R410A |
R410A |
Water
connection diameter (in/out) |
inches |
1/2" (gas) |
3/4" (gas) |
Condensate
drain connection diameter (inside or outside) |
mm |
18 |
18 |
Heat
transferred to water |
kW |
3,47 |
3,35 |
Heat moved
from water |
kW |
- |
- |
Heating
capacity in water Radiator mode |
kW |
2,1 |
Power input
/ Running consumption in water radiator mdoe |
kW / A |
0,027 / 0,01 |
Water flowrate
in water radiator mode |
m³/h |
0,19 |
Pressure drops
in water radiator mode |
kPa |
2,9 |
Hydraulic
connection diameter to the heating plant (w.r. mode) |
inches |
1/2" |
Sound pressure level
at 2 m/ Sound power level - water radiator mode (HS-MS-LS) |
dB(A) |
42-39-32 / 50-47-40 |
Net weight |
Kg |
46 |
Net dimension (H./W./D.) |
mm |
735/839/260-280 |
Town
water - Cooling - Room Temp. 27°C d.b./ 19°C w.b. - Water
Temp.: inlet 18°C - outlet 36°C / Water radiator - Room Temp.
20°C - Water Temp.: inlet 70°C - outlet 60°
Water loop - Cooling - Room Temp. 27°C d.b. / 19°C w.b. -
Water Temp.: inlet 30°C - outlet 35°C / Water radiator -
Room Temp. 20°C - Water Temp.: inlet 70°C - outlet 60°C
*Water loop (definition
EN14511) - Closed circuit of water maintained within a
temperature range on which the units in cooling mode reject
heat and the units in heating mode take heat.
|
Infrared remote control with digital timer and temperature sensor inside

Optional joint kit for hydraulic
connection to the heating plant
Optional support kit for floor
special installations
|