Rêve 237R H2O
-
Cooling only and heat pump
air conditoner
+ water radiator
-
Water-cooled
-
To be freely installed: not necessarily on a perimetral wall,
without holes in the wall
-
Very high energy efficiency
-
Very low energy consumption
-
External sound level lower than the
air-cooled version
-
Ozone friendly refrigerant: R410A
|
- Packaged double-duct straight cooling and heat
pump
air-conditioner + water radiator (with optional joint kit for
connection to the heating plant)
- Water-cooled condensation with a water medium consumption
of about 1 m3 for a 8 hour operation.
- To be freely installed, not necessarily on a
perimetral wall, because no holes in the wall are requested.
- Designed to operate with both town water and
wellwater or groundwater; it can be used also as terminal unit of a
closed circuit system (water loop) with water at 30°C, according to
EN14511 standard specifications.
- High efficiency spiral heat exchanger.
- Solenoid valve to stop the town water flowrate when
the compressor is off.
- Anti-freeze protection on the condensation water
circuit.
- It's suggested the installation of a filter to be
inspected on the entry of the town water (by the installer).
- Automatic change-over between cooling and
heating modes.
- Infrared remote control with 24h digital timer
.
- Double temperature sensor (on the unit and
inside the remote control); double temperature indication (set and
room).
- Dry only function.
- Ventilation only function.
- "I Feel" feature, granting the best comfort
conditions.
- "Sleep" feature, with automatic
adaptation to the night temmperatures.
- Horizontal flap swinging or to be set to a
fixed position by remote control.
- Vertical flap by manual control.
- Anti-mould and anti-bacteria washable filters.
- Three-speed tangential fan with auto or speed
manual selection.
- "Cold Draft Prevention" device with water
temperature < 40°C in water radiator mode and with evaporator
temperature < 40°C
- High precision thermostat with adjustment from
6°C to 40°C in water radiator mode.
- Heating function disabled during defrosting cycle.
- Auto restart after a black out, saving all
feature parameters set before the power failure.
- Electronic protection against over-pressures.
- Optional joint kit for hydraulic connection to
the heating plant (with three-way bypass valve included) necessary
only in water radiator mode.
- Special optional support kit of two small feet
for floor installations (glass walls, etc.).
- HFC refrigerant R410A.
- High efficiency rotary compressor.
| MODEL |
MROF 235 R5T |
Operation |
with
town water |
in
water loop*
(standard conditions EN14511) |
Features |
Unit |
Cooling |
Heating |
Cooling |
Heating |
Cooling/Heating capacity in air-conditioner mode |
kW |
2,95 |
3,15 |
3,00 |
3,56 |
BTU/h |
10.060 |
10.740 |
10.230 |
12.140 |
kcal/h |
2.540 |
2.710 |
2.580 |
3.060 |
Energy efficiency class |
ABCDEFG |
- |
- |
A |
C |
E.E.R. / C.O.P. |
(kW/kW) |
4,68 |
3,80 |
4,41 |
4,14 |
Air flowrate (HS-MS-LS) |
m³/h |
330-300-280 |
330-300-280 |
Dehumidification |
l/h |
1,3 |
1,3 |
Fan speeds |
n° |
3 + Auto |
3 + Auto |
Sound pressure level
at 2 m/ Sound power level - air-conditioner mode (HS-MS-LS) |
dB(A) |
44-42-41/52/50/49 |
44-42-41/52/50/49 |
Power supply |
V/Ph/Hz |
230/1/50 |
Power
input
/ Running current in air-conditioner mode |
kW / A |
0,630/2,8 |
0,830/3,8 |
0,680/3,0 |
0,860/3,8 |
Annual energy consumption in Cooling
mode - (500h) |
kWh |
- |
- |
340 |
- |
Water flowrate
for the heat exchanger |
m³/h |
0,150 |
0,525 |
Pressure drops |
KPa |
2,9 |
40,3 |
Refrigerant type |
|
R410A |
R410A |
Water
connection diameter (in/out) |
inches |
1/2" (gas) |
3/4" (gas) |
Condensate
drain connection diameter (inside or outside) |
mm |
18 |
18 |
Heat
transferred to water |
kW |
3,58 |
- |
3,68 |
- |
Heat moved
from water |
kW |
- |
2,04 |
- |
2,7 |
Heating
capacity in water Radiator mode |
kW |
2,1 |
Power input
/ Running consumption in water radiator mdoe |
kW / A |
0,027 / 0,01 |
Water flowrate
in water radiator mode |
m³/h |
0,19 |
Pressure drops
in water radiator mode |
kPa |
2,9 |
Hydraulic
connection diameter to the heating plant (w.r. mode) |
inches |
1/2" |
Sound pressure level
at 2 m/ Sound power level - water radiator mode (HS-MS-LS) |
dB(A) |
42-39-32 / 50-47-40 |
Net weight |
Kg |
48 |
Net dimension (H./W./D.) |
mm |
735x839x260-280 |
Town
water - Cooling: Room Temp. 27°C d.b. / 19°C w.b. - Water
Temp. : inlet 18°C - outlet 36°C / Heat Pump : Room Temp.
20°C d.b. - Water Temp.: inlet 18°C outlet 6°C
Water loop - Cooling: Room Temp . 27°C d.b. / 19°C w.b. -
Water Temp.: inlet 30°C - outlet 35°C / Heat Pump : Room
Temp. 20°C d.b. - Water Temp. 15°C
Water radiator - Room Temp. 20°C - Water Temp.: inlet 70°C -
outlet 60°C
*Water loop (definition
EN14511) - Closed circuit of water maintained within a
temperature range on which the units in cooling mode reject
heat and the units in heating mode take heat.
|
Infrared remote control with digital timer and temperature sensor inside

Optional joint kit for hydraulic
connection to the heating plant
Optional support kit for floor
special installations
|