Technibel
Rêve 237R H2O
  • Cooling only and heat pump
    air conditoner +  water radiator 
  • Water-cooled
  • To be freely installed: not necessarily on a  perimetral wall, without holes in the wall
  • Very high energy efficiency
  • Very low energy consumption
  • External sound level lower than the air-cooled version
  • Ozone friendly refrigerant: R410A
  • Packaged double-duct straight cooling and heat pump air-conditioner + water radiator (with optional joint kit for connection to the heating plant)
  • Water-cooled condensation with a water medium consumption of about 1  m3 for a 8 hour operation.
  • To be freely installed, not necessarily on a perimetral wall, because no holes in the wall are requested.
  • Designed to operate with both town water and wellwater or groundwater; it can be used also as terminal unit of a closed circuit system (water loop) with water at 30°C, according to EN14511 standard specifications.
  • High efficiency spiral heat exchanger.
  • Solenoid valve to stop the town water flowrate when the compressor is off.
  • Anti-freeze protection on the condensation water circuit.
  • It's suggested the installation of a filter to be inspected on the entry of the town water (by the installer).
  • Automatic change-over between cooling and heating modes.
  • Infrared remote control with 24h digital timer .
  • Double temperature sensor (on the unit and inside the remote control); double temperature indication (set and room).
  • Dry only function.
  • Ventilation only function.
  • "I Feel" feature, granting the best comfort conditions.
  • "Sleep" feature, with automatic adaptation to the night temmperatures.
  • Horizontal flap swinging or to be set to a fixed position by remote control.
  • Vertical flap by manual control.
  • Anti-mould and anti-bacteria washable filters.
  • Three-speed tangential fan with auto or speed manual selection.
  • "Cold Draft Prevention" device with water temperature < 40°C in water radiator mode and with evaporator temperature < 40°C
  • High precision thermostat with adjustment from 6°C to 40°C in water radiator mode.
  • Heating function disabled during defrosting cycle.
  • Auto restart after a black out, saving all feature parameters set before the power failure.
  • Electronic protection against over-pressures.
  • Optional joint kit for hydraulic connection to the heating plant (with three-way bypass valve included) necessary only in water radiator mode.
  • Special optional support kit of two small feet for floor installations (glass walls, etc.).
  • HFC refrigerant R410A.
  • High efficiency rotary compressor.

MODEL
MROF 235 R5T
Operation
with town water
in water loop*

(standard conditions EN14511)

Features
Unit
Cooling
Heating
Cooling
Heating
Cooling/Heating capacity in air-conditioner mode
kW
2,95
3,15
3,00
3,56
BTU/h
10.060
10.740
10.230
12.140
kcal/h
2.540
2.710
2.580
3.060
Energy efficiency class
ABCDEFG
-
-
A
C
E.E.R. / C.O.P.
(kW/kW)
4,68
3,80
4,41
4,14
Air flowrate (HS-MS-LS)
m³/h
330-300-280
330-300-280
Dehumidification
l/h
1,3
1,3
Fan speeds
3 + Auto
3 + Auto
Sound pressure level at 2 m/ Sound power level  - air-conditioner mode (HS-MS-LS)
dB(A)
44-42-41/52/50/49
44-42-41/52/50/49
Power supply
V/Ph/Hz
230/1/50
Power input / Running current in air-conditioner mode
kW / A
0,630/2,8
0,830/3,8
0,680/3,0
0,860/3,8
Annual energy consumption in Cooling mode - (500h)
kWh
-
-
340
-
Water flowrate for the heat exchanger
m³/h
0,150
0,525
Pressure drops
KPa
2,9
40,3
Refrigerant type
R410A
R410A
Water connection diameter  (in/out)
inches
1/2" (gas)
3/4" (gas)
Condensate drain connection diameter (inside or outside)
mm
18
18
Heat transferred to water
kW
3,58
-
3,68
-
Heat moved from water
kW
-
2,04
-
2,7
Heating capacity in water Radiator mode
kW
2,1
Power input / Running consumption in water radiator mdoe
kW / A
0,027 / 0,01
Water flowrate in water radiator mode
m³/h
0,19
Pressure drops in water radiator mode
kPa
2,9
Hydraulic connection diameter to the heating plant (w.r. mode)
inches
1/2"
Sound pressure level at 2 m/ Sound power level  - water radiator mode (HS-MS-LS)
dB(A)
42-39-32 / 50-47-40
Net weight
Kg
48
Net dimension (H./W./D.)
mm
735x839x260-280
Town water - Cooling: Room Temp. 27°C d.b. / 19°C w.b. - Water Temp. : inlet 18°C - outlet 36°C / Heat Pump : Room Temp. 20°C d.b. - Water Temp.: inlet 18°C outlet 6°C
Water loop - Cooling: Room Temp . 27°C d.b. / 19°C w.b. - Water Temp.: inlet 30°C - outlet 35°C / Heat Pump : Room Temp. 20°C d.b. - Water Temp. 15°C
Water radiator - Room Temp. 20°C - Water Temp.: inlet 70°C - outlet 60°C

*Water loop (definition EN14511) - Closed circuit of water maintained within a temperature range on which the units in cooling mode reject heat and the units in heating mode take heat.



 

Infrared remote control with digital timer and temperature sensor inside

Optional joint kit for hydraulic connection to the heating plant
 

 Optional support kit for floor special installations

 


User ID
Password