This solution is a radiator-based CENTRAL HEATING
system, with the possibilty of producing domestic hot water (DHW).
The
air/water heat pump and the MCE heating module provides the full heating
needs of a dwelling.
Usual names:
- "Boiler substitution" in NEW or
EXISTING installations
- "Heating with 1 zone of radiators" in
NEW installations
Several good reasons to choose the air/water Heat Pump
in spite of a fuel boiler:
- This solution allows to optimize the existing
heating plants.
- It's particularly suitable in the case of
refurbishment of central heating systems which burn fossil
energies (fuel, propane, natural gas).
- The high temperature Heat Pump provides the full needs of heating and domestic hot water production.
- Energy consumption is considerably reduced as
the heat pump recovers free calories from the ambient air leading to
less consumption of fossil-fuel-fired energy and electricity.
- For example, by using a Heat Pump, the emission
of greenhouse gases (CO2) is reduced by a factor of 24 in
comparison with a fuel oil boiler.
- This solution enables the customer to satisfy
his legitimate desire to reduce his heating bills and, at the same
time, to take part in the worldwide reduction of energy
consumption and of the emission of greenhouse gases.
- Moreover, for the investments in Air/Water Heat Pump
like principal source of heating of its own house, many European countries
recognize financial benefits, depending on the Financial Law of each
particular state.
|
|
The available accessories are :
Additional electric
heater module - MCE8
or MCE10, control unit included
- The additional electric heater module grants the
heating complement of Your installation when the Heat Pump is not enough.
- This module is controlled by the electronic
regulation and privileges the thermodynamic heating to contribute to the
power consumption reduction.
- Flexibility in use: to answer with precision to
your need for heating, the additional module has 2 stages of power.
- Flexibility in installation:it can be installed
outside directly on the heat pump or inside in technical room.
- Safety: the module is equipped with 2 thermal
safety measures (1 with automatic rearmament and 1 with manual
rearmament) and with a pressure controller of lack of water.
Models |
Electric
heating capacity
(kW) |
Heat
Pump models concerned |
MCE8 |
7,5 (5 + 2,5) |
PHTJ14 - PHRT
7-9-12-16 |
MCE10 |
9,9 (6,6 + 3,3) |
PHTJ19 - PHT13-16 - PHRT
12-16 (three-phase
models only) |
|
Additional electric heater module
MCE8 or MCE10
 |