Technibel

  • Ducted heat pump indoor units for
    Multi-simultaneous systems
  • Infrared receiver and remote controller (models 125/165/185)
  • Infrared remote controller or wired remote controller (option) - model 255
  • Easy modification of the static pressure
    on site
  • Integrated pump for condensate discharge
  • With or without 2/3 duct plenum (DSAFP125/165/185).
  • 3-way air diffusion (DSAFP 255).
  • Automatic change-over between cooling and heating modes.
  • Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room.
  • Among the control units available for this kind of indoor unit (all optional) (DSAFP125/165/185):
    -  the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the
       the best comfort conditions ("I Feel" feature);
    - a special wired controller with configuration, diagnostic and weekly timer capabilities, which can be matched with weekly timer and control system.
  • Temperature sensor integrated in the infrared remote contoller.
  • "I Feel" feature, granting the best comfort conditions.
  • Dry function.
  • Night set back capability.
  • Three-speed centrifugal fan by remote control, with static pressure variable from 50 to  70 Pa (DSAFP 125/165/185).
  • Three-speed centrifugal and available pressure from 50 to 100 Pa (DSAF P255).
  • Easy modification of the static pressure on site.
  • Anti-mould and anti-bacteria washable filters (except for DSAFP255).
  • Integrated pump for condensate discharge.
  • Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor.
INDOOR UNITS  for MULTI-SIMULTANEOUS SYSTEMS - DC INVERTER

DSAFP 125 R5I

DSAFP 165 R5I

DSAFP 185 R5I

DSAFP 255 R5I

Features
Unit
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling / Heating capacity
kW
3,6
4,2
4,7
5,2
5,6
6,3
7,3
8,0
BTU/h
12.280
14.320
16.030
17.730
19.100
21.480
24.900
27.280
kcal/h
4.000
3.610
4.040
4.470
4.820
5.420
6.280
6.880
Air flowrate (HS-MS-LS)
m³/h
600-510-440
875-600-400
875-600-400
1080-900-780
Dehumidification
l/h
1,5
-
2,3
-
2,3
-
3,5
-
External Static pressure (min.-max.)
Pa
50-70 with booster cable
50-70 with booster cable
50-70 with booster cable
50-70 with booster cable
Fan speeds
3 + Auto 
3 + Auto 
3 + Auto 
3 + Auto 
Sound power  level I.U. (HS-MS-LS)
dB(A)
45-43-40
45-38-33
45-38-33
34-30-27
Sound pressure level I.U.  (HS-MS-LS)  at plenum connection
dB(A)
54-52-49
54-47-42
54-47-42
43-39-36
Power supply
V/Ph/Hz
230/1/50
230/1/50
230/1/50
230/1/50
Power input
kW
0,11
0,11
0,138
0,138
0,138
0,138
0,195
0,183
Running current
A
0,58
0,49
0,60
0,60
0,60
0,60
0,84
0,84
Liquid pipe diameter
mm (inches)
6,35(1/4")
6,35(1/4")
6,35(1/4")
9,52(3/8")
Gas pipe diameter
mm (inches)
12,7 (1/2")
12,7 (1/2")
12,7 (1/2")
15,88(5/8")
Internal diameter of condensate drain pipe
mm 
20
20
20
32
Net weight I.U. /  I.U.with plenum
Kg
30 / 36
30 / 36
35  / 42,5
35  / 42,5
Net dimension I.U.(H./W./D.)
mm
266x926x571
266x926x571
266x1132x571
310x1000x630
Net dimension I.U. with plenum (H./W./D.)
mm
266x926x771
266x1132x771
266x1132x771
-
 
 


User ID