8 models from 24 to 76 kW
-
High compact units
-
Refrigerant R407C
-
Complete hydraulic equipment
incorporated
-
Electronic control system
|
- Heat pumps intended for heating and air-conditioning
of commercial buildings.
- Compact units to be installed outside.
- Ozone friendly refrigerant R407C for the respect of the environment.
- Higher coefficients of performances thanks to
the augmentation of the available hydraulic pressure.
- Scroll compressor with
sound insulation, high performance fin heat exchanger with
protection grill, axial fan motor with variable speed control
and heat protection, heat exchanger with AISI 316 stainless steel
plates and heat insulation, etc.
- Units ready to operate, with hydraulic
equipment incorporated : 3-speed circulating pump, expansion
tank, safety valve, air bleed valve, water pressure control,
hydraulic filter.
- Complete equipment: the PHRV Heat Pumps are
equipped with the following safety systems: high and low pressure
switch, water flow switch, anti-freeze safety.
- Proportional head pressure control.
- Electronic control by microprocessor (with keypad)
which optimizes the operation of the Heat Pump and grants the
following functions:
- Temperature control of hot water and cold water
- Self-adapting algorithm allowing the reduction
of the water volume (elimination of the buffer receiver vessel)
- Control of the operating parameters
- Automatic control of the circulating pump (anti-freeze and
anti-seize fonction)
- Counting of the operating time of compressor and circulator
- Defrosting adjusted according to the outdoor temperature
- Condensation pressure control
- Alarm management
- External communication via a serial inerface (Protocol
Modbus) (accessory)
- Output for controlling an additional
electronic device (not supplied).
- Phase sequence tester.
- Additional electrical heating (in option).
- Easy access to all components.

| MODELS |
PHRV 22 |
PHRV 25 |
PHRV 32 |
PHRV 36 |
Outdoor unit
Features |
400/3N/50 |
PHRV 227 V |
PHRV 257 V |
PHRV 327 V |
PHRV 367 V |
Unit |
Heating |
Cooling |
Heating |
Cooling |
Heating |
Cooling |
Heating |
Cooling |
Cooling/Heating capacity |
kW |
24,0 |
20,8 |
27,3 |
25,8 |
35,5 |
30,3 |
38,4 |
33,5 |
Power input |
kW |
9,0 |
8,85 |
10,4 |
9,7 |
13,55 |
13,55 |
14,75 |
14,55 |
C.O.P/E.E.R. |
(kW/kW) |
2,67 |
2,35 |
2,63 |
2,66 |
2,62 |
2,24 |
2,60 |
2,30 |
Water flow |
m³/h |
4,21 |
3,47 |
4,70 |
4,50 |
5,93 |
5,21 |
7,22 |
6,05 |
Available head pump |
Kpa |
185 |
215 |
145 |
160 |
140 |
200 |
95 |
165 |
Refrigerant type |
|
R407C |
R407C |
R407C |
R407C |
Nb of refrigerant circuits |
no. |
1 |
1 |
1 |
1 |
Nb of compressors |
no. |
1 |
1 |
1 |
1 |
Expansion tank capacity |
l |
8 |
8 |
8 |
8 |
Water connector diameter
- male |
(inches) |
1" 1/4 |
1" 1/4 |
1" 1/4 |
1" 1/4 |
Sound pressure level (HS) at 10 m** |
dB(A) |
51 |
50 |
52 |
54 |
Sound power level (HS) |
dB(A) |
79 |
78 |
80 |
82 |
Net dimension (H./W./D.) |
mm |
1175x975x1050 |
1175x975x1050 |
1175x975x1050 |
1425x975x1050 |
Net weight |
Kg |
303 |
305 |
327 |
363 |
| MODELS |
PHRV 44 |
PHRV 50 |
PHRV 64 |
PHRV 72 |
Outdoor unit
Features |
400/3N/50 |
PHRV 447 V |
PHRV 507 V |
PHRV 647 V |
PHRV 727 V |
Unit |
Heating |
Cooling |
Heating |
Cooling |
Heating |
Cooling |
Heating |
Cooling |
| Puissance calorifique/frigorifique |
kW |
49,0 |
40,6 |
54,0 |
52,6 |
69,3 |
60,6 |
77,30 |
66,2 |
| Puissance absorbée |
kW |
17,80 |
17,70 |
19 |
21,2 |
27 |
27,10 |
30,5 |
28,8 |
| C.O.P. /E.E.R. |
(kW/kW) |
2,75 |
2,29 |
2,84 |
2,48 |
2,57 |
2,24 |
2,53 |
2,3 |
| Débit d'eau |
m³/h |
8,42 |
6,98 |
9,29 |
9,04 |
11,92 |
10,44 |
13,32 |
11,41 |
| Available head pump |
Kpa |
215 |
260 |
180 |
200 |
150 |
210 |
120 |
200 |
Refrigerant type |
|
R407C |
R407C |
R407C |
R407C |
Nb of refrigerant circuits |
no. |
2 |
2 |
2 |
2 |
Nb of compressors |
no. |
2 |
2 |
2 |
2 |
Expansion tank capacity |
l |
18 |
18 |
18 |
18 |
Water connector diameter
- male |
(inches) |
1" 1/2 |
1" 1/2 |
1" 1/2 |
1" 1/2 |
Sound pressure level (HS) at 10 m** |
dB(A) |
50 |
48 |
52 |
57 |
Sound power level (HS) |
dB(A) |
78 |
76 |
80 |
85 |
Net dimension (H./W./D.) |
mm |
1175x1955x1050 |
1175x1955x1050 |
1175x1955x1050 |
1425x1955x1050 |
Net weight |
Kg |
516 |
520 |
554 |
626 |
*Sound pressure: this level corresponds to that of a unit installed
outdoor (free sound field), on a reflective surface, with the
measurement being taken at a distance of 10 m.
COMPRESSOR (1)
Hermetic Scroll (1 for each refrigerant circuit), with acoustic
hooding and internal motor protection, mounted on anti-vibration
supports.
AIR / REFRIGERANT EXCHANGER (2)
"L" exchanger with protection grill, alluminium fins on copper
tubes - Equipped with a temperature sensor for the condensation pressure
control.
AXIAL FAN (3)
1 fan (direct drive) for each refrigerant circuit, with heat
protection - Variable speed for the operation at low outdoor
temperatures.
High efficiency WATER / REFRIGERANT
EXCHANGER (4)
1 exchanger for each refrigerant circuit - Heat exchanger with
stainless steel brazed plates and heat insulation: it allows an
otpimized heat exchanger with a reduced quantity of refrigerant -
Refrigerated water and anti-freeze sensors.
REFRIGERANT CIRCUIT (5)
Refrigerant R407C -
Thermostatic pressure reducer -
Dehydrator filter -
High and Low pressure controllers - Cycle inversion valve -
Mixing tank
INTGRATED HYDRAULIC MODULE (6)
Circulating pump with insulation - Filling valve -
Manometer / Safety valve 3 bar -
Air vent - Control valve -
Expansion tank -
Water flow differential pressure controller.
SWITCHBOX (7)
Compliant with the standard EN 60 204-1 - Protection of the order
and power circuits by magnetothermal circuit breakers -
Phase sequence tester.
ELECTRONIC CONTROL KEYPAD/DISPLAY (8)
FRAME - OUTER COVER (9)
Made of coated sheet with strong thickness, polyester
powder painted, clear grey colour.
|
|
Commercial models
Residential models
|